Tel : +90 216 341 70 70
Fax : +90 216 341 70 99
E-mail : edison@edison.com.tr

Pressure & Temperature Instruments

Rangeable Pressure Transducer

GC30
Ultra-Compact Digital Differential Pressure Sensor Model GC30

Size: 30x30x46 mm,
Accuracy: 1,5 %,
Metric Range Min: 0 ... 50 Pa, Metric Range Max: 0 ... 5 kPa,
Imperial Range Min: 0 ... 0,25 in. H2O, Imperial Range Max: 0 ... 25 in. H2O


Applications: Filter monitoring, Clean room pressure differential, Vacuum/suction pressure sensing and

control, Fan speed control

GC31
Ultra-Compact Digital Pressure Sensor Model GC31

Size: 30x30x40 mm,
Accuracy: 1 %,
Metric Range Min: 0 ... 1 MPa, Metric Range Max: 0 ... 50 MPa,
Imperial Range Min: 0 ... 50 psi, Imperial Range Max: 0 ... 1.500 psi


Applications: Hydraulic presses, stamping equipment, lifts, Tire press vulcanization, pressure monitoring,

Water, refrigerant or ammonia based cooling systems, Pressure monitoring on lubrication systems

GC35
Digital Pressure Sensor Model GC35

Size: 34x52x72 mm,
Accuracy: 1 %,
Metric Range Min: 0 ... 4 bar, Metric Range Max: 0 ... 600 bar,
Imperial Range Min: 0 ... 50 psi, Imperial Range Max: 0 ... 7.500 psi


Applications: Hydraulic presses, stamping equipment, lifts, Water/wastewater pressure control, Water, refrigerant or ammonia based cooling systems, Pressure monitoring on lubrication systems

GC51
Rangeable Pressure Transmitter Model GC51

Size: 65 mm,
Accuracy: 0,25 %,
Metric Range Min: -1 ... 1 bar, Metric Range Max: 0 ... 517 bar,
Imperial Range Min: -30 in. Hg ... 15 psi, Imperial Range Max: 0 ... 7.500 psi


Applications: The GC51 utilizes Ashcrofts’ proven polysilicon thin film sensor which makes the design suitable for applications where high overpressure and high cycle life are necessary, typically required in Pump Control, Hydraulic Systems, Compressor Control, Process Automation, Municipal Water Tank Level

GC52
Rangeable Wet/Wet Differential Pressure Transmitter Model GC52

Size: 65 mm,
Accuracy: 0,5 %,
Metric Range Min: 0 ... 10 mbar, Metric Range Max: 0 ... 1 bar,
Imperial Range Min: 0 ... 4 in. H2O, Imperial Range Max: 0 ... 200 in. H2O


Applications: The GC52 utilizes Ashcrofts’ proven Si-Glas™ silicon variable capacitance sensor technology in a wet-wet package ideal for applications where reliable, low differential pressure measurement is required with line (static) pressure to 300 psi. Applications include Pressurized and non-pressurized tank levels. In addition, this instrument offers flow measurement/square root extraction, where the momentary flow rate can be displayed and analog signal can be output.

GC55
Wet/Wet Differential Pressure Transducer Model GC55

Size: 70x100x40 mm,
Accuracy: 0,5 %,
Metric Range Min: 0 ... 5 bar, Metric Range Max: 0 ... 20 bar,
Imperial Range Min: 0 ... 75 psi, Imperial Range Max: 0 ... 300 psi


Applications: The new Ashcroft® Model GC55 is a compact high differential pressure transducer, ideal for filter

monitoring, HVAC hydronic cooling and heating systems and pump controls.